Every factory, warehouse, hospital and office tower in Saudi Arabia depends on electrical systems — and on the technicians who install, test and maintain them. That work carries some of the most severe hazards on any site: electric shock, electrocution, arc flash and arc blast. Arc flash training in Saudi Arabia based on NFPA 70E gives your technical teams the knowledge and discipline to work safely, every time.
At Sustainability Leaders Company (SLC) in Riyadh, we deliver practical Electrical Safety and Arc Flash Training based on NFPA 70E (2024 edition), delivered on-site for technical personnel across the Kingdom.
What is an arc flash, and why is it so dangerous?
An arc flash happens when electric current jumps through the air between conductors, or from a conductor to ground. The energy is released in a fraction of a second as intense heat, light, pressure, sound and molten metal.
- Extreme heat: arc temperatures can reach about 19,400 °C — roughly four times the surface of the sun.
- Speed: a typical arcing fault can cause severe burns in less than 0.1 seconds, faster than anyone can react.
- Arc blast: the pressure wave can throw workers, burst enclosure doors and rupture ear drums.
- Clothing ignition: at 4–8 cal/cm², ordinary non-arc-rated clothing can ignite and keep burning on the body.
A curable second-degree burn begins at just 1.2 cal/cm² — the level NFPA 70E uses to set the arc flash boundary. Electric shock is just as serious: current through the body, even from ordinary 230/400 V systems, can stop the heart.
What NFPA 70E requires
NFPA 70E, the Standard for Electrical Safety in the Workplace, sets out the safe work practices, maintenance requirements and administrative controls that protect people working on or near electrical equipment. It is revised every three years; the current edition is 2024. Its core principles are:
- De-energise first: put equipment into an electrically safe work condition using lockout/tagout and test for absence of voltage. Energized work is allowed only when justified, and normally needs an energized electrical work permit.
- Assess the risk: carry out shock and arc flash risk assessments, set approach boundaries and label equipment. The arc flash risk assessment is reviewed at least every five years.
- Select the right PPE: use arc-rated clothing and equipment chosen by incident energy analysis or the PPE category method (categories 1–4, rated 4 to 40 cal/cm²).
- Train and verify: employers must train workers, audit the lockout/tagout programme annually and verify emergency response training — including CPR and AED — every year.
NFPA 70E and Saudi requirements
In Saudi Arabia, the duty to protect workers sits with the employer. Saudi Labour Law and the MHRSD occupational safety and health regulations require employers to provide training and suitable protective equipment. The Saudi Building Code — SBC 401 (Electrical) — covers the design and installation of electrical systems, while NFPA 70E gives the practical method for working safely on them. PPE supplied in the Kingdom must also hold SASO conformity through the SABER platform.
What our arc flash training covers
The course is built around five modules, each linked to the 2024 edition of NFPA 70E and to Saudi requirements:
- NFPA 70E and electrical hazards — scope of the standard, employer and employee responsibilities, electric shock, electrocution, arc flash and arc blast.
- Electrically safe work condition — when energized work is justified, the 8-step process, safe work zones, lockout/tagout, absence-of-voltage testing and energized work permits.
- Risk assessment and approach boundaries — shock and arc flash risk assessment, incident energy analysis, arc flash boundaries and equipment labels.
- PPE and safe tools — PPE categories 1–4, selection methods, rubber insulating gloves, inspection and care, and voltage-rated tools.
- Safe work practices and emergency response — job briefings, JSA and risk mitigation, safe release of victims, CPR and AED, and incident reporting.
Sessions are interactive, with real electrical incident case studies, arc flash label and PPE selection exercises, and job briefing and JSA practice.
Benefits of NFPA 70E training for your company
- Protect lives: prevent electric shock, electrocution and arc flash burns through safe work practices.
- Meet legal duties: support Saudi Labour Law, MHRSD OSH rules and the Saudi Building Code alongside NFPA 70E.
- De-energise first: lockout/tagout, test before touch and energized work permits done the right way.
- The right PPE, every time: arc-rated PPE, rubber gloves and insulated tools selected and cared for correctly.
- Protect equipment and uptime: better maintenance and job planning reduce the chance of arc faults and unplanned outages.
- Be audit-ready: job briefings, JSAs, permits and arc flash labels that stand up to client and insurer audits.
Who should attend
The course is designed for technical personnel: electricians and electrical technicians, electrical and maintenance engineers, supervisors and permit issuers, HSE officers, facility and plant managers, and electrical contractors working on client sites.
Why choose SLC
SLC is a Riyadh-based health and safety training and consultancy company. Alongside internationally recognised NEBOSH courses, we design specialist training around the real hazards of our clients' sites — from ammonia refrigeration to electrical systems. Our NFPA 70E arc flash training is delivered on-site at your facility, tailored to your equipment and procedures, and every participant receives an SLC certificate of completion.
Frequently asked questions
What is NFPA 70E?
NFPA 70E is the Standard for Electrical Safety in the Workplace, published by the National Fire Protection Association. It sets out safe work practices to protect people from electric shock, electrocution, arc flash and arc blast. The current edition is 2024.
What is arc flash training?
Arc flash training teaches workers to recognise arc flash and shock hazards, put equipment into an electrically safe work condition, assess risk, use arc flash boundaries and labels, and select and care for arc-rated PPE.
Is NFPA 70E training required in Saudi Arabia?
Saudi Labour Law and the MHRSD OSH regulations require employers to train workers and provide suitable protective equipment. NFPA 70E is the internationally recognised method for doing this for electrical work, and many clients and insurers in the Kingdom expect it.
What are the arc flash PPE categories?
NFPA 70E defines four PPE categories with minimum arc ratings of 4, 8, 25 and 40 cal/cm². The category, or a calculated incident energy, is shown on the equipment's arc flash label.
Who needs arc flash training?
Anyone who works on or near exposed energized electrical equipment — electricians, technicians, engineers, supervisors and permit issuers — and HSE staff who oversee electrical work.
How long is the course, and do participants get a certificate?
The course runs over one day and is delivered on-site at your facility. Every participant who completes it receives an SLC certificate of completion.
Book NFPA 70E arc flash training for your team
An arc flash is over in a fraction of a second — preparation is what makes the difference. Contact SLC to arrange on-site Electrical Safety and Arc Flash Training at your facility anywhere in Saudi Arabia.
Sustainability Leaders Company (SLC)
4265 Ghazzah St – Al Wadi District, Riyadh 13313 – 6788, Saudi Arabia
Tel: +966 11 495 8604
Mobile / WhatsApp: +966 50 596 5227 | +966 53 658 1681
Email: admin@slcgrouponline.com
Web: www.slcgrouponline.com
Sources (for the web team)
- NFPA 70E, Standard for Electrical Safety in the Workplace, 2024 edition: https://www.nfpa.org/70E
- Saudi Building Code SBC 401 (Electrical): https://sbc.gov.sa
- MHRSD — Equipping the work environment (Labour Law Art. 121–123): https://hrsd.gov.sa/en/knowledge-centre/articles/64379
- SLC course material: Electrical Safety & Arc Flash Training (NFPA 70E)